{"title":"Wholesale Solar Mounting Systems Worldwide","description":"\u003cp\u003e\n  Explore Worldwide Solar mounting systems for wholesale supply worldwide. Our range includes aluminium and ZAM steel ballast mounting systems for flat roofs and ground installations, as well as mounting solutions for mesh fencing.\n\u003c\/p\u003e\n\n\u003cp\u003e\n  Choose from full pallet quantities or full container loads to suit your project, distribution or commercial requirements. Prices are \u003cstrong\u003eFOB Xiamen, China\u003c\/strong\u003e, with flexible international freight, destination-port and door-to-door delivery options available on request.\n\u003c\/p\u003e","products":[{"product_id":"worldwide-solar-model-1-10-solar-ballast-mounting-full-pallet","title":"Worldwide Solar Model 1 – 10° Solar Ballast Mounting – Full Pallet","description":"\u003cdiv style=\"font-family:Arial, sans-serif; line-height:1.6;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eWorldwide Solar Model 1 – 10° Aluminium Ballast Solar Mounting System\u003c\/strong\u003e is a premium mounting solution specifically designed for \u003cstrong\u003eground-mounted, garden and flat roof solar installations\u003c\/strong\u003e. Manufactured from high-strength, corrosion-resistant aluminium, Model 1 combines structural strength with straightforward installation, providing a reliable and durable foundation for residential, commercial and off-grid photovoltaic systems.\u003c\/p\u003e\n\n\u003cp\u003eThe optimised \u003cstrong\u003e10° fixed tilt angle\u003c\/strong\u003e supports efficient solar energy generation while maintaining excellent stability in outdoor environments. Its ballast design eliminates the need for permanent concrete foundations or ground penetration, making installation faster, more flexible and easier to relocate when required.\u003c\/p\u003e\n\n\u003cp\u003eWorldwide Solar Model 1 has been engineered in accordance with \u003cstrong\u003eEN 1991-1-4:2005 (Eurocode – Wind Actions)\u003c\/strong\u003e. The manufacturer has confirmed that this is equivalent to the corresponding British Standard for structural wind loading. The calculations are based on a \u003cstrong\u003e30 m\/s sustained mean wind speed (108 km\/h \/ 67 mph)\u003c\/strong\u003e, \u003cstrong\u003eTerrain Category III\u003c\/strong\u003e and an assumed installation height of up to \u003cstrong\u003e10 metres\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe required ballast depends on the mounting configuration, local wind conditions and site exposure. Ballast values are provided for \u003cstrong\u003eWind Fetch Categories I–IV\u003c\/strong\u003e and for both single-direction and opposing-direction mounting configurations.\u003c\/p\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorldwide Solar Model 1\u003c\/strong\u003e aluminium ballast mounting system\u003c\/li\u003e\n\u003cli\u003eSupports up to \u003cstrong\u003efour framed solar panels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for \u003cstrong\u003eground-mounted, garden and flat roof installations\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptimised \u003cstrong\u003e10° fixed tilt angle\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh-strength, corrosion-resistant aluminium construction\u003c\/li\u003e\n\u003cli\u003eNo permanent concrete foundations or ground penetration required\u003c\/li\u003e\n\u003cli\u003eFast and straightforward installation\u003c\/li\u003e\n\u003cli\u003eSuitable for single-direction and opposing-direction configurations\u003c\/li\u003e\n\u003cli\u003eCompatible with optional wind deflectors\u003c\/li\u003e\n\u003cli\u003eDesigned in accordance with \u003cstrong\u003eEN 1991-1-4:2005\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesign wind speed of \u003cstrong\u003e30 m\/s sustained mean wind speed\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eBallast guidance for \u003cstrong\u003eWind Fetch Categories I–IV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for residential, commercial and off-grid solar projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px; table-layout:fixed;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003eGENERAL DATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eWorldwide Solar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eModel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e10° Aluminium Ballasted Solar Mounting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eInstallation Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eGround-Mounted \/ Garden \/ Flat Roof\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eHigh-strength aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eSurface Finish\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCorrosion-resistant aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eTilt Angle\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e10° fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePanels Supported\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e4 framed solar panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eMounting Configurations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eSingle-direction or opposing-direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003eENGINEERING \u0026amp; PERFORMANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eDesign Standard\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eEN 1991-1-4:2005 (Eurocode – Wind Actions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eBritish Standard Equivalent\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eYes, as confirmed by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eDesign Wind Speed\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e30 m\/s sustained mean wind speed (108 km\/h \/ 67 mph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eExposure Category\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTerrain Category III\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eDesign Height\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eUp to 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eWind Fetch Categories\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eI–IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eWind Deflector Compatible\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eBallast Requirement\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eDepends on the Wind Fetch Category and mounting configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eBallast Stones Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e12 solid concrete stones per complete four-panel set\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003eAPPLICATIONS\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eResidential Gardens\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eCommercial Ground Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eOff-Grid Solar Systems\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eTemporary or Relocatable Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eFlat Roof Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePitched Roof Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✘\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eTypical Ballast Requirements per Ballast Stone\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px; table-layout:fixed;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold; text-align:left;\"\u003eWind Fetch Category\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold; text-align:center;\"\u003eConfiguration A\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold; text-align:center;\"\u003eConfiguration B\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eI\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e28 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eII\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e36 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eIII\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e45 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eIV\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e55 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"margin-top:18px;\"\u003e\n\u003cstrong\u003eConfiguration A – Single-Direction Mounting\u003c\/strong\u003e\u003cbr\u003e\nAll four solar panels are installed at a fixed \u003cstrong\u003e10° tilt\u003c\/strong\u003e facing the same direction. This arrangement is suitable where the array is intended to generate energy from one principal orientation.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eConfiguration B – Opposing-Direction Mounting\u003c\/strong\u003e\u003cbr\u003e\nThe four solar panels are installed in two opposing rows, with each row facing in the opposite direction. This configuration generally requires less ballast per stone than Configuration A.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eBallast Requirement\u003c\/strong\u003e\u003cbr\u003e\nEach complete \u003cstrong\u003eWorldwide Solar Model 1\u003c\/strong\u003e four-panel mounting system requires \u003cstrong\u003e12 solid concrete ballast stones\u003c\/strong\u003e. The table shows the recommended minimum weight of each individual stone according to the Wind Fetch Category and mounting configuration.\n\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:20px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#EAF8EF; border:1px solid #B8E8CA; border-left:5px solid #08B85A; padding:18px; vertical-align:top;\"\u003e\n\n\u003ch4 style=\"margin:0 0 12px 0; color:#008C45; font-size:18px;\"\u003eRecommended Ballast Stones\u003c\/h4\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nWorldwide Solar has identified the following solid concrete block sizes that fit the Model 1 mounting system:\n\u003c\/p\u003e\n\n\u003cul style=\"margin:0 0 14px 20px; padding-left:0;\"\u003e\n\u003cli style=\"margin-bottom:6px;\"\u003e\n\u003cstrong\u003e440 × 100 × 215 mm\u003c\/strong\u003e (L × W × H) — approximately \u003cstrong\u003e23 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e440 × 150 × 215 mm\u003c\/strong\u003e (L × W × H) — approximately \u003cstrong\u003e34 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThese suggested block sizes are suitable for most scenarios shown in the ballast table.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThe approximately \u003cstrong\u003e23 kg block\u003c\/strong\u003e is suitable for \u003cstrong\u003eConfiguration B, Wind Fetch Categories I–III\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThe approximately \u003cstrong\u003e34 kg block\u003c\/strong\u003e is suitable for \u003cstrong\u003eall Configuration B categories\u003c\/strong\u003e and \u003cstrong\u003eConfiguration A, Wind Fetch Category I\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nFor \u003cstrong\u003eConfiguration A, Wind Fetch Categories II–IV\u003c\/strong\u003e, these block sizes do not provide sufficient individual stone weight. Heavier solid concrete ballast stones or another suitable ballast arrangement must therefore be used.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0;\"\u003e\nOnly \u003cstrong\u003esolid, normal-weight concrete\u003c\/strong\u003e blocks should be used. Lightweight, hollow or aerated concrete blocks are not suitable for use as ballast. The stated weights are approximate and may vary according to the concrete density and manufacturer.\n\u003c\/p\u003e\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size:13px; color:#666; margin-top:15px;\"\u003e\nBallast values are based on the manufacturer’s calculations using a reference solar panel size of \u003cstrong\u003e2000 × 1134 × 30 mm\u003c\/strong\u003e. Actual ballast requirements may vary depending on local wind conditions, site exposure, terrain category, panel dimensions and installation configuration.\n\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Worldwide Solar","offers":[{"title":"Default Title","offer_id":58468212048255,"sku":"WWS-BRK-KX1-M1-4P-P24","price":85.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/6479\/0911\/files\/Model_1_B.webp?v=1784673847"},{"product_id":"worldwide-solar-model-2-20-zam-ballast-mounting-system-full-pallet","title":"Worldwide Solar Model 2 – 20° ZAM Ballast Mounting System – Full Pallet","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta name=\"viewport\" content=\"width=device-width,initial-scale=1\"\u003e\u003ctitle\u003eWorldwide Solar Model 2 – Product Description\u003c\/title\u003e\n\u003cdiv style=\"font-family:Arial,sans-serif;line-height:1.6;color:#222;max-width:1050px;margin:auto;padding:12px;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eWorldwide Solar Model 2 – 20° ZAM Steel Ballast Solar Mounting System\u003c\/strong\u003e is a compact, durable solution for \u003cstrong\u003esingle-panel ground-mounted and suitable flat-roof solar installations\u003c\/strong\u003e. Manufactured from high-strength \u003cstrong\u003eZAM steel\u003c\/strong\u003e, it combines straightforward assembly with a ballasted, non-penetrating design.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ezinc-aluminium-magnesium (ZAM) coating\u003c\/strong\u003e helps protect the steel against outdoor corrosion and has a \u003cstrong\u003eC3 corrosion-resistance classification\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe fixed \u003cstrong\u003e20° tilt angle\u003c\/strong\u003e provides a compact installation profile. The system supports \u003cstrong\u003eone framed solar panel weighing up to 38 kg\u003c\/strong\u003e with a frame thickness of \u003cstrong\u003e30–40 mm\u003c\/strong\u003e. The table below lists five panel dimensions and their corresponding ballast figures.\u003c\/p\u003e\n\u003cp\u003eThe stated design specifications are a \u003cstrong\u003e30 m\/s wind speed\u003c\/strong\u003e and \u003cstrong\u003e1.0 kN\/m² snow load\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 style=\"margin-top:25px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorldwide Solar Model 2\u003c\/strong\u003e single-panel mounting system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20° fixed tilt\u003c\/strong\u003e and ballasted, non-penetrating design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZAM-coated steel\u003c\/strong\u003e with C3 corrosion classification\u003c\/li\u003e\n\u003cli\u003eFor ground installations and suitable flat roofs\u003c\/li\u003e\n\u003cli\u003eSupports one framed panel up to \u003cstrong\u003e38 kg\u003c\/strong\u003e; frame thickness \u003cstrong\u003e30–40 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eBallast figures provided for \u003cstrong\u003efive panel sizes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesign conditions: \u003cstrong\u003e30 m\/s wind\u003c\/strong\u003e and \u003cstrong\u003e1.0 kN\/m² snow load\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompact package: \u003cstrong\u003e650 × 190 × 110 mm\u003c\/strong\u003e; \u003cstrong\u003e6.2 kg\u003c\/strong\u003e (mounting kit, excluding ballast)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin-top:25px;\"\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;table-layout:fixed;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:10px;border:1px solid #ccc;background:#08B85A;color:#fff;font-weight:bold;\"\u003eGENERAL DATA\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eWorldwide Solar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eModel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e20° ZAM Steel Ballast Solar Mounting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eMounting Component Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eBallast bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eInstallation Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eGround-mounted and suitable flat-roof installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eMaterial \/ Finish\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eZAM steel \/ zinc-aluminium-magnesium coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eCorrosion Resistance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eC3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eTilt Angle\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e20° fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003ePanels Supported\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e1 framed solar panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:10px;border:1px solid #ccc;background:#08B85A;color:#fff;font-weight:bold;\"\u003ePANEL COMPATIBILITY\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003ePanel Sizes Covered by Ballast Specifications\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e1762, 1953, 1954, 2063 and 2333 mm long × 1134 mm wide × 30 mm thick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eCompatible Frame Thickness\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e30–40 mm, subject to clamp compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eMaximum Panel Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:10px;border:1px solid #ccc;background:#08B85A;color:#fff;font-weight:bold;\"\u003eENGINEERING \u0026amp; PERFORMANCE\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eWind Load Design Reference\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eEN 1991-1-4:2005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eStated Design Wind Speed\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e30 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eStated Design Snow Load\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e1.0 kN\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eBallast Requirement\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eSee the per-side ballast table below for each panel size and installation environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:10px;border:1px solid #ccc;background:#08B85A;color:#fff;font-weight:bold;\"\u003ePRODUCT \u0026amp; PACKAGING DATA\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003ePackage Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e650 × 190 × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003ePackage Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e6.2 kg (excluding ballast stones)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin-top:25px;\"\u003eApplications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;table-layout:fixed;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:10px;border:1px solid #ccc;background:#08B85A;color:#fff;font-weight:bold;\"\u003eSUITABLE INSTALLATIONS\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003eResidential garden installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#008C45;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003eFlat roof installations (check structural load capacity)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#008C45;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003eCommercial ground installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#008C45;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003eOff-grid solar systems\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#008C45;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003eTemporary or relocatable installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#008C45;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003ePitched roof installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#cc0000;\"\u003e✘\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003csection style=\"background:#EAF8EF;border:1px solid #B8E8CA;border-left:5px solid #08B85A;padding:18px;margin:20px 0;\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#008C45;font-size:18px;\"\u003eBallast Requirements – Weight per Side\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003eThe table shows the \u003cstrong\u003eballast weight per side of each solar panel\u003c\/strong\u003e for the five panel sizes. Each Model 2 mounting system has two ballast sides. \u003cstrong\u003eFor flat-roof installations, use the open-field \/ exposed figures as the minimum reference.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13px;min-width:590px;text-align:left;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#08B85A;color:#fff;\"\u003e\n\u003cth style=\"padding:10px;border:1px solid #b8e8ca;\"\u003ePanel size (mm)\u003c\/th\u003e\n\u003cth style=\"padding:10px;border:1px solid #b8e8ca;\"\u003eOpen field \/ exposed\u003cbr\u003eCalculated weight\u003c\/th\u003e\n\u003cth style=\"padding:10px;border:1px solid #b8e8ca;\"\u003eUrban \/ residential\u003cbr\u003eEstimated\u003c\/th\u003e\n\u003cth style=\"padding:10px;border:1px solid #b8e8ca;\"\u003eSheltered garden\u003cbr\u003eEstimated\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e1762 × 1134 × 30\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e\u003cstrong\u003e58.8 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e35.3 kg\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e17.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#EAF8EF;\"\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e1953 × 1134 × 30\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e\u003cstrong\u003e87 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e52.2 kg\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e26.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e1954 × 1134 × 30\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e\u003cstrong\u003e90 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e54 kg\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#EAF8EF;\"\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e2063 × 1134 × 30\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e\u003cstrong\u003e95 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e57 kg\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e28.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e2333 × 1134 × 30\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e\u003cstrong\u003e104 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e62.4 kg\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e31.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0 0;font-size:13px;\"\u003e\u003cstrong\u003eDesign basis:\u003c\/strong\u003e 20° tilt, 30 m\/s wind speed and 1.0 kN\/m² snow load. The open-field figures are calculated for these conditions. The urban and sheltered-garden figures are estimates based on potentially reduced wind exposure. Ballast requirements vary with installation location, surrounding structures, local wind conditions and supporting surface.\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0;font-size:13px;\"\u003eUse solid, normal-weight concrete ballast stones, securely positioned in the designated ballast areas. Concrete ballast stones are \u003cstrong\u003enot included\u003c\/strong\u003e and must be purchased separately.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection style=\"background:#FFF8E5;border:1px solid #F2D98D;border-left:5px solid #E4A900;padding:18px;margin:20px 0;\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#A87500;font-size:18px;\"\u003eImportant Installation Information\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 10px;\"\u003eConcrete ballast stones are not included. Ballast requirements can change with site conditions and installation location.\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eBefore installation, ensure the supporting surface can carry the combined weight of the mounting system, solar panel and ballast. \u003cstrong\u003eFor flat roofs, use the open-field \/ exposed ballast figures as the minimum reference\u003c\/strong\u003e and check the roof's load capacity.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003cp style=\"font-size:13px;color:#666;margin-top:15px;\"\u003eProduct specifications and performance values are provided by Worldwide Solar Ltd. Installation requirements depend on site conditions and applicable regulations.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Worldwide Solar","offers":[{"title":"Default Title","offer_id":58469519556991,"sku":"WWS-BRK-KX1-M2-1P-P90","price":14.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/6479\/0911\/files\/Model-2-1.webp?v=1784892642"},{"product_id":"worldwide-solar-model-3-mesh-fence-solar-panel-mounting-full-pallet","title":"Worldwide Solar Model 3 – Mesh Fence Solar Panel Mounting – Full Pallet","description":"\u003cdiv style=\"font-family:Arial, sans-serif; line-height:1.6; color:#222;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eWorldwide Solar Model 3 – Mesh Fence Solar Panel Mounting System\u003c\/strong\u003e provides a practical and space-efficient solution for mounting framed solar panels directly onto suitable mesh fencing. Designed for straightforward installation, the system allows photovoltaic modules to be securely attached to an existing fence without requiring a separate ground-mounted support structure.\u003c\/p\u003e\n\n\u003cp\u003eThe mounting system uses adjustable \u003cstrong\u003eupper clamps\u003c\/strong\u003e that attach to suitable mounting holes on the rear of the solar panel frame. The left and right clamps can be adjusted according to the spacing of the fence mesh before the bolt assemblies are tightened securely.\u003c\/p\u003e\n\n\u003cp\u003eThe system supports both \u003cstrong\u003evertical (portrait)\u003c\/strong\u003e and \u003cstrong\u003ehorizontal (landscape)\u003c\/strong\u003e solar panel installation, providing flexibility according to the available fence area and the orientation of the solar module.\u003c\/p\u003e\n\n\u003cp\u003eThe lower clamp arrangement is designed for framed solar panels with a frame thickness of \u003cstrong\u003e30–35 mm\u003c\/strong\u003e. According to the manufacturer’s installation manual, the mounting system is suitable for \u003cstrong\u003e656\/868 fence configurations\u003c\/strong\u003e. :contentReference[oaicite:0]{index=0}\u003c\/p\u003e\n\n\u003cp\u003eOnce installed, the upper and lower mounting components work together to secure the solar panel firmly against the fence. This makes Worldwide Solar Model 3 particularly suitable where an existing compatible mesh fence can provide the supporting structure for a space-saving photovoltaic installation.\u003c\/p\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eKey Features\u003c\/h3\u003e\n\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorldwide Solar Model 3\u003c\/strong\u003e mesh fence solar panel mounting system\u003c\/li\u003e\n\u003cli\u003eDesigned for mounting solar panels directly onto suitable mesh fencing\u003c\/li\u003e\n\u003cli\u003eSupports \u003cstrong\u003eone framed solar panel per mounting set\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003evertical (portrait) installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003ehorizontal (landscape) installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eVertical mounting position of approximately \u003cstrong\u003e90°\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible with solar panel frame thicknesses of \u003cstrong\u003e30–35 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjustable upper clamps allow positioning according to fence mesh spacing\u003c\/li\u003e\n\u003cli\u003eUpper clamps attach to suitable mounting holes in the rear solar panel frame\u003c\/li\u003e\n\u003cli\u003eLower clamps secure the bottom of the solar panel against the fence\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003e656\/868 fence configurations\u003c\/strong\u003e as stated by the manufacturer\u003c\/li\u003e\n\u003cli\u003eNo separate ground-mounted solar frame required where a suitable mesh fence is available\u003c\/li\u003e\n\u003cli\u003eSpace-efficient mounting solution for suitable residential, commercial and off-grid solar projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px; table-layout:fixed;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003e\nGENERAL DATA\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eWorldwide Solar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eModel 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMesh Fence Solar Panel Mounting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eMounting Component Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eSolar Panel Mesh Fence Clamp System\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eInstallation Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMesh Fence-Mounted Solar Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePanel Orientation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eVertical (Portrait) or Horizontal (Landscape)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eTilt Angle\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eVertical (90°)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePanels Supported\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e1 framed solar panel per mounting set\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003e\nPANEL COMPATIBILITY\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eCompatible Panel Thickness\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e30–35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePanel Orientation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePortrait or Landscape\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePanel Attachment\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eUpper clamps attach through suitable mounting holes in the rear panel frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003e\nMESH FENCE COMPATIBILITY\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eCompatible Fence Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eSuitable mesh fencing\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eFence Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e656 \/ 868, as specified by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eUpper Clamp Adjustment\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eAdjustable according to fence mesh spacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eLower Clamp Arrangement\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eOne lower clamp positioned on each side of the panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eApplications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px; table-layout:fixed;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003e\nSUITABLE INSTALLATIONS\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:70%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eMesh Fence Solar Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eVertical \/ Portrait Solar Panels\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eHorizontal \/ Landscape Solar Panels\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eResidential Solar Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eCommercial Solar Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eOff-Grid Solar Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eGround Ballast Installation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#cc0000;\"\u003e✘\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eFlat Roof Installation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#cc0000;\"\u003e✘\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:20px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#EAF8EF; border:1px solid #B8E8CA; border-left:5px solid #08B85A; padding:18px; vertical-align:top;\"\u003e\n\n\u003ch4 style=\"margin:0 0 12px 0; color:#008C45; font-size:18px;\"\u003e\nHow the Mesh Fence Mounting System Works\n\u003c\/h4\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThe upper clamps are first installed into suitable mounting holes on the rear of the solar panel frame. Their position can be adjusted according to the spacing of the fence mesh before the bolt assemblies are tightened.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThe solar panel is then positioned against the mesh fence. The wedge fittings are reinstalled and tightened to secure the upper section of the panel to the fence.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0;\"\u003e\nLower clamps are installed beneath the solar panel, with one clamp positioned on each side. The support piece, locking block and front pressure plate work together to hold the panel firmly against the fence.\n\u003c\/p\u003e\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:20px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#FFF8E5; border:1px solid #F2D98D; border-left:5px solid #E4A900; padding:18px; vertical-align:top;\"\u003e\n\n\u003ch4 style=\"margin:0 0 12px 0; color:#A87500; font-size:18px;\"\u003e\nImportant Installation Information\n\u003c\/h4\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nBefore installation, the purchaser or installer must confirm that installation of the system is permitted under applicable local laws, regulations and property requirements.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nInstallation should be carried out by a suitably qualified installer or professional where required by law. The mesh fence and supporting structure must be capable of safely supporting the solar panel and mounting system for the intended service life.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThe product should not be installed in environments containing corrosive air or water, including areas exposed to acids or alkalis.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0;\"\u003e\nThe installed system should be inspected and maintained periodically. The manufacturer's instructions specify inspection intervals of no more than one year.\n\u003c\/p\u003e\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size:13px; color:#666; margin-top:15px;\"\u003e\nProduct specifications and installation information are based on documentation supplied by the manufacturer. Suitability depends on the solar panel, mesh fence construction, installation location and applicable local requirements. The installer must confirm that the mesh fence and supporting structure are suitable for the intended photovoltaic installation before installation begins.\n\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Worldwide Solar","offers":[{"title":"Default Title","offer_id":58469578441087,"sku":"WWS-BRK-KX1-M3-1P-P576","price":9.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/6479\/0911\/files\/mesh-fence-solar-panel-mount-front.webp?v=1786466194"},{"product_id":"worldwide-solar-model-1-10-aluminium-ballast-mount-full-container","title":"Worldwide Solar Model 1 – 10° Aluminium Ballast Mount – Full Container","description":"\u003cdiv style=\"font-family:Arial, sans-serif; line-height:1.6;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eWorldwide Solar Model 1 – 10° Aluminium Ballast Solar Mounting System\u003c\/strong\u003e is a premium mounting solution specifically designed for \u003cstrong\u003eground-mounted, garden and flat roof solar installations\u003c\/strong\u003e. Manufactured from high-strength, corrosion-resistant aluminium, Model 1 combines structural strength with straightforward installation, providing a reliable and durable foundation for residential, commercial and off-grid photovoltaic systems.\u003c\/p\u003e\n\n\u003cp\u003eThe optimised \u003cstrong\u003e10° fixed tilt angle\u003c\/strong\u003e supports efficient solar energy generation while maintaining excellent stability in outdoor environments. Its ballast design eliminates the need for permanent concrete foundations or ground penetration, making installation faster, more flexible and easier to relocate when required.\u003c\/p\u003e\n\n\u003cp\u003eWorldwide Solar Model 1 has been engineered in accordance with \u003cstrong\u003eEN 1991-1-4:2005 (Eurocode – Wind Actions)\u003c\/strong\u003e. The manufacturer has confirmed that this is equivalent to the corresponding British Standard for structural wind loading. The calculations are based on a \u003cstrong\u003e30 m\/s sustained mean wind speed (108 km\/h \/ 67 mph)\u003c\/strong\u003e, \u003cstrong\u003eTerrain Category III\u003c\/strong\u003e and an assumed installation height of up to \u003cstrong\u003e10 metres\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe required ballast depends on the mounting configuration, local wind conditions and site exposure. Ballast values are provided for \u003cstrong\u003eWind Fetch Categories I–IV\u003c\/strong\u003e and for both single-direction and opposing-direction mounting configurations.\u003c\/p\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorldwide Solar Model 1\u003c\/strong\u003e aluminium ballast mounting system\u003c\/li\u003e\n\u003cli\u003eSupports up to \u003cstrong\u003efour framed solar panels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for \u003cstrong\u003eground-mounted, garden and flat roof installations\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptimised \u003cstrong\u003e10° fixed tilt angle\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh-strength, corrosion-resistant aluminium construction\u003c\/li\u003e\n\u003cli\u003eNo permanent concrete foundations or ground penetration required\u003c\/li\u003e\n\u003cli\u003eFast and straightforward installation\u003c\/li\u003e\n\u003cli\u003eSuitable for single-direction and opposing-direction configurations\u003c\/li\u003e\n\u003cli\u003eCompatible with optional wind deflectors\u003c\/li\u003e\n\u003cli\u003eDesigned in accordance with \u003cstrong\u003eEN 1991-1-4:2005\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesign wind speed of \u003cstrong\u003e30 m\/s sustained mean wind speed\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eBallast guidance for \u003cstrong\u003eWind Fetch Categories I–IV\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for residential, commercial and off-grid solar projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px; table-layout:fixed;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003eGENERAL DATA\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eWorldwide Solar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eModel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e10° Aluminium Ballasted Solar Mounting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eInstallation Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eGround-Mounted \/ Garden \/ Flat Roof\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eMaterial\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eHigh-strength aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eSurface Finish\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCorrosion-resistant aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eTilt Angle\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e10° fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePanels Supported\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e4 framed solar panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eMounting Configurations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eSingle-direction or opposing-direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003eENGINEERING \u0026amp; PERFORMANCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eDesign Standard\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eEN 1991-1-4:2005 (Eurocode – Wind Actions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eBritish Standard Equivalent\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eYes, as confirmed by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eDesign Wind Speed\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e30 m\/s sustained mean wind speed (108 km\/h \/ 67 mph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eExposure Category\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTerrain Category III\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eDesign Height\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eUp to 10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eWind Fetch Categories\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eI–IV\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eWind Deflector Compatible\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eBallast Requirement\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eDepends on the Wind Fetch Category and mounting configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eBallast Stones Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e12 solid concrete stones per complete four-panel set\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003eAPPLICATIONS\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eResidential Gardens\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eCommercial Ground Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eOff-Grid Solar Systems\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eTemporary or Relocatable Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eFlat Roof Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePitched Roof Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e✘\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eTypical Ballast Requirements per Ballast Stone\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px; table-layout:fixed;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold; text-align:left;\"\u003eWind Fetch Category\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold; text-align:center;\"\u003eConfiguration A\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold; text-align:center;\"\u003eConfiguration B\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eI\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e28 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eII\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e36 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eIII\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e45 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eIV\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e55 kg\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center;\"\u003e29 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"margin-top:18px;\"\u003e\n\u003cstrong\u003eConfiguration A – Single-Direction Mounting\u003c\/strong\u003e\u003cbr\u003e\nAll four solar panels are installed at a fixed \u003cstrong\u003e10° tilt\u003c\/strong\u003e facing the same direction. This arrangement is suitable where the array is intended to generate energy from one principal orientation.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eConfiguration B – Opposing-Direction Mounting\u003c\/strong\u003e\u003cbr\u003e\nThe four solar panels are installed in two opposing rows, with each row facing in the opposite direction. This configuration generally requires less ballast per stone than Configuration A.\n\u003c\/p\u003e\n\n\u003cp\u003e\n\u003cstrong\u003eBallast Requirement\u003c\/strong\u003e\u003cbr\u003e\nEach complete \u003cstrong\u003eWorldwide Solar Model 1\u003c\/strong\u003e four-panel mounting system requires \u003cstrong\u003e12 solid concrete ballast stones\u003c\/strong\u003e. The table shows the recommended minimum weight of each individual stone according to the Wind Fetch Category and mounting configuration.\n\u003c\/p\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:20px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#EAF8EF; border:1px solid #B8E8CA; border-left:5px solid #08B85A; padding:18px; vertical-align:top;\"\u003e\n\n\u003ch4 style=\"margin:0 0 12px 0; color:#008C45; font-size:18px;\"\u003eRecommended Ballast Stones\u003c\/h4\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nWorldwide Solar has identified the following solid concrete block sizes that fit the Model 1 mounting system:\n\u003c\/p\u003e\n\n\u003cul style=\"margin:0 0 14px 20px; padding-left:0;\"\u003e\n\u003cli style=\"margin-bottom:6px;\"\u003e\n\u003cstrong\u003e440 × 100 × 215 mm\u003c\/strong\u003e (L × W × H) — approximately \u003cstrong\u003e23 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e440 × 150 × 215 mm\u003c\/strong\u003e (L × W × H) — approximately \u003cstrong\u003e34 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThese suggested block sizes are suitable for most scenarios shown in the ballast table.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThe approximately \u003cstrong\u003e23 kg block\u003c\/strong\u003e is suitable for \u003cstrong\u003eConfiguration B, Wind Fetch Categories I–III\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThe approximately \u003cstrong\u003e34 kg block\u003c\/strong\u003e is suitable for \u003cstrong\u003eall Configuration B categories\u003c\/strong\u003e and \u003cstrong\u003eConfiguration A, Wind Fetch Category I\u003c\/strong\u003e.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nFor \u003cstrong\u003eConfiguration A, Wind Fetch Categories II–IV\u003c\/strong\u003e, these block sizes do not provide sufficient individual stone weight. Heavier solid concrete ballast stones or another suitable ballast arrangement must therefore be used.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0;\"\u003e\nOnly \u003cstrong\u003esolid, normal-weight concrete\u003c\/strong\u003e blocks should be used. Lightweight, hollow or aerated concrete blocks are not suitable for use as ballast. The stated weights are approximate and may vary according to the concrete density and manufacturer.\n\u003c\/p\u003e\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size:13px; color:#666; margin-top:15px;\"\u003e\nBallast values are based on the manufacturer’s calculations using a reference solar panel size of \u003cstrong\u003e2000 × 1134 × 30 mm\u003c\/strong\u003e. Actual ballast requirements may vary depending on local wind conditions, site exposure, terrain category, panel dimensions and installation configuration.\n\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Worldwide Solar","offers":[{"title":"20 ft Container – 384 Sets","offer_id":58470720110975,"sku":"WWS-BRK-KX1-M1-4P-C20-384","price":85.0,"currency_code":"GBP","in_stock":true},{"title":"40 ft HC Container – 1008 Sets","offer_id":58470720143743,"sku":"WWS-BRK-KX1-M1-4P-C40HC-1008","price":85.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/6479\/0911\/files\/Model_1_B.webp?v=1784673847"},{"product_id":"worldwide-solar-model-2-20-zam-ballast-mounting-system-full-container","title":"Worldwide Solar Model 2 – 20° ZAM Ballast Mounting System – Full Container","description":"\u003cmeta charset=\"utf-8\"\u003e\u003cmeta name=\"viewport\" content=\"width=device-width,initial-scale=1\"\u003e\u003ctitle\u003eWorldwide Solar Model 2 – Product Description\u003c\/title\u003e\n\u003cdiv style=\"font-family:Arial,sans-serif;line-height:1.6;color:#222;max-width:1050px;margin:auto;padding:12px;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eWorldwide Solar Model 2 – 20° ZAM Steel Ballast Solar Mounting System\u003c\/strong\u003e is a compact, durable solution for \u003cstrong\u003esingle-panel ground-mounted and suitable flat-roof solar installations\u003c\/strong\u003e. Manufactured from high-strength \u003cstrong\u003eZAM steel\u003c\/strong\u003e, it combines straightforward assembly with a ballasted, non-penetrating design.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003ezinc-aluminium-magnesium (ZAM) coating\u003c\/strong\u003e helps protect the steel against outdoor corrosion and has a \u003cstrong\u003eC3 corrosion-resistance classification\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe fixed \u003cstrong\u003e20° tilt angle\u003c\/strong\u003e provides a compact installation profile. The system supports \u003cstrong\u003eone framed solar panel weighing up to 38 kg\u003c\/strong\u003e with a frame thickness of \u003cstrong\u003e30–40 mm\u003c\/strong\u003e. The table below lists five panel dimensions and their corresponding ballast figures.\u003c\/p\u003e\n\u003cp\u003eThe stated design specifications are a \u003cstrong\u003e30 m\/s wind speed\u003c\/strong\u003e and \u003cstrong\u003e1.0 kN\/m² snow load\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 style=\"margin-top:25px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorldwide Solar Model 2\u003c\/strong\u003e single-panel mounting system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20° fixed tilt\u003c\/strong\u003e and ballasted, non-penetrating design\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZAM-coated steel\u003c\/strong\u003e with C3 corrosion classification\u003c\/li\u003e\n\u003cli\u003eFor ground installations and suitable flat roofs\u003c\/li\u003e\n\u003cli\u003eSupports one framed panel up to \u003cstrong\u003e38 kg\u003c\/strong\u003e; frame thickness \u003cstrong\u003e30–40 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eBallast figures provided for \u003cstrong\u003efive panel sizes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesign conditions: \u003cstrong\u003e30 m\/s wind\u003c\/strong\u003e and \u003cstrong\u003e1.0 kN\/m² snow load\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompact package: \u003cstrong\u003e650 × 190 × 110 mm\u003c\/strong\u003e; \u003cstrong\u003e6.2 kg\u003c\/strong\u003e (mounting kit, excluding ballast)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin-top:25px;\"\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;table-layout:fixed;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:10px;border:1px solid #ccc;background:#08B85A;color:#fff;font-weight:bold;\"\u003eGENERAL DATA\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eWorldwide Solar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eModel 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e20° ZAM Steel Ballast Solar Mounting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eMounting Component Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eBallast bracket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eInstallation Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eGround-mounted and suitable flat-roof installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eMaterial \/ Finish\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eZAM steel \/ zinc-aluminium-magnesium coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eCorrosion Resistance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eC3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eTilt Angle\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e20° fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003ePanels Supported\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e1 framed solar panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:10px;border:1px solid #ccc;background:#08B85A;color:#fff;font-weight:bold;\"\u003ePANEL COMPATIBILITY\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003ePanel Sizes Covered by Ballast Specifications\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e1762, 1953, 1954, 2063 and 2333 mm long × 1134 mm wide × 30 mm thick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eCompatible Frame Thickness\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e30–40 mm, subject to clamp compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eMaximum Panel Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:10px;border:1px solid #ccc;background:#08B85A;color:#fff;font-weight:bold;\"\u003eENGINEERING \u0026amp; PERFORMANCE\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eWind Load Design Reference\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eEN 1991-1-4:2005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eStated Design Wind Speed\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e30 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eStated Design Snow Load\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e1.0 kN\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003eBallast Requirement\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eSee the per-side ballast table below for each panel size and installation environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:10px;border:1px solid #ccc;background:#08B85A;color:#fff;font-weight:bold;\"\u003ePRODUCT \u0026amp; PACKAGING DATA\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003ePackage Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e650 × 190 × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:40%;padding:10px;border:1px solid #ccc;\"\u003ePackage Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e6.2 kg (excluding ballast stones)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin-top:25px;\"\u003eApplications\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;table-layout:fixed;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\" style=\"padding:10px;border:1px solid #ccc;background:#08B85A;color:#fff;font-weight:bold;\"\u003eSUITABLE INSTALLATIONS\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003eResidential garden installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#008C45;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003eFlat roof installations (check structural load capacity)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#008C45;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003eCommercial ground installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#008C45;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003eOff-grid solar systems\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#008C45;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003eTemporary or relocatable installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#008C45;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"width:70%;padding:10px;border:1px solid #ccc;\"\u003ePitched roof installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;text-align:center;color:#cc0000;\"\u003e✘\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003csection style=\"background:#EAF8EF;border:1px solid #B8E8CA;border-left:5px solid #08B85A;padding:18px;margin:20px 0;\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#008C45;font-size:18px;\"\u003eBallast Requirements – Weight per Side\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 12px;\"\u003eThe table shows the \u003cstrong\u003eballast weight per side of each solar panel\u003c\/strong\u003e for the five panel sizes. Each Model 2 mounting system has two ballast sides. \u003cstrong\u003eFor flat-roof installations, use the open-field \/ exposed figures as the minimum reference.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x:auto;\"\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13px;min-width:590px;text-align:left;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#08B85A;color:#fff;\"\u003e\n\u003cth style=\"padding:10px;border:1px solid #b8e8ca;\"\u003ePanel size (mm)\u003c\/th\u003e\n\u003cth style=\"padding:10px;border:1px solid #b8e8ca;\"\u003eOpen field \/ exposed\u003cbr\u003eCalculated weight\u003c\/th\u003e\n\u003cth style=\"padding:10px;border:1px solid #b8e8ca;\"\u003eUrban \/ residential\u003cbr\u003eEstimated\u003c\/th\u003e\n\u003cth style=\"padding:10px;border:1px solid #b8e8ca;\"\u003eSheltered garden\u003cbr\u003eEstimated\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e1762 × 1134 × 30\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e\u003cstrong\u003e58.8 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e35.3 kg\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e17.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#EAF8EF;\"\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e1953 × 1134 × 30\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e\u003cstrong\u003e87 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e52.2 kg\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e26.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e1954 × 1134 × 30\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e\u003cstrong\u003e90 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e54 kg\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e27 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#EAF8EF;\"\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e2063 × 1134 × 30\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e\u003cstrong\u003e95 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e57 kg\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e28.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e2333 × 1134 × 30\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e\u003cstrong\u003e104 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e62.4 kg\u003c\/td\u003e\n\u003ctd style=\"padding:9px;border:1px solid #b8e8ca;\"\u003e31.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:12px 0 0;font-size:13px;\"\u003e\u003cstrong\u003eDesign basis:\u003c\/strong\u003e 20° tilt, 30 m\/s wind speed and 1.0 kN\/m² snow load. The open-field figures are calculated for these conditions. The urban and sheltered-garden figures are estimates based on potentially reduced wind exposure. Ballast requirements vary with installation location, surrounding structures, local wind conditions and supporting surface.\u003c\/p\u003e\n\u003cp style=\"margin:10px 0 0;font-size:13px;\"\u003eUse solid, normal-weight concrete ballast stones, securely positioned in the designated ballast areas. Concrete ballast stones are \u003cstrong\u003enot included\u003c\/strong\u003e and must be purchased separately.\u003c\/p\u003e\u003c\/section\u003e\n\u003csection style=\"background:#FFF8E5;border:1px solid #F2D98D;border-left:5px solid #E4A900;padding:18px;margin:20px 0;\"\u003e\n\u003ch3 style=\"margin:0 0 10px;color:#A87500;font-size:18px;\"\u003eImportant Installation Information\u003c\/h3\u003e\n\u003cp style=\"margin:0 0 10px;\"\u003eConcrete ballast stones are not included. Ballast requirements can change with site conditions and installation location.\u003c\/p\u003e\n\u003cp style=\"margin:0;\"\u003eBefore installation, ensure the supporting surface can carry the combined weight of the mounting system, solar panel and ballast. \u003cstrong\u003eFor flat roofs, use the open-field \/ exposed ballast figures as the minimum reference\u003c\/strong\u003e and check the roof's load capacity.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003cp style=\"font-size:13px;color:#666;margin-top:15px;\"\u003eProduct specifications and performance values are provided by Worldwide Solar Ltd. Installation requirements depend on site conditions and applicable regulations.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Worldwide Solar","offers":[{"title":"20 ft Container – 1280 Sets","offer_id":58470745407871,"sku":"WWS-BRK-KX1-M2-1P-C20-1280","price":14.0,"currency_code":"GBP","in_stock":true},{"title":"40 ft HC Container – 3240 Sets","offer_id":58470745440639,"sku":"WWS-BRK-KX1-M2-1P-C40HC-3240","price":14.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/6479\/0911\/files\/Model-2-1.webp?v=1784892642"},{"product_id":"worldwide-solar-model-3-mesh-fence-solar-panel-mount-full-container","title":"Worldwide Solar Model 3 – Mesh Fence Solar Panel Mount – Full Container","description":"\u003cdiv style=\"font-family:Arial, sans-serif; line-height:1.6; color:#222;\"\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eWorldwide Solar Model 3 – Mesh Fence Solar Panel Mounting System\u003c\/strong\u003e provides a practical and space-efficient solution for mounting framed solar panels directly onto suitable mesh fencing. Designed for straightforward installation, the system allows photovoltaic modules to be securely attached to an existing fence without requiring a separate ground-mounted support structure.\u003c\/p\u003e\n\n\u003cp\u003eThe mounting system uses adjustable \u003cstrong\u003eupper clamps\u003c\/strong\u003e that attach to suitable mounting holes on the rear of the solar panel frame. The left and right clamps can be adjusted according to the spacing of the fence mesh before the bolt assemblies are tightened securely.\u003c\/p\u003e\n\n\u003cp\u003eThe system supports both \u003cstrong\u003evertical (portrait)\u003c\/strong\u003e and \u003cstrong\u003ehorizontal (landscape)\u003c\/strong\u003e solar panel installation, providing flexibility according to the available fence area and the orientation of the solar module.\u003c\/p\u003e\n\n\u003cp\u003eThe lower clamp arrangement is designed for framed solar panels with a frame thickness of \u003cstrong\u003e30–35 mm\u003c\/strong\u003e. According to the manufacturer’s installation manual, the mounting system is suitable for \u003cstrong\u003e656\/868 fence configurations\u003c\/strong\u003e. :contentReference[oaicite:0]{index=0}\u003c\/p\u003e\n\n\u003cp\u003eOnce installed, the upper and lower mounting components work together to secure the solar panel firmly against the fence. This makes Worldwide Solar Model 3 particularly suitable where an existing compatible mesh fence can provide the supporting structure for a space-saving photovoltaic installation.\u003c\/p\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eKey Features\u003c\/h3\u003e\n\n\u003cul style=\"padding-left:22px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorldwide Solar Model 3\u003c\/strong\u003e mesh fence solar panel mounting system\u003c\/li\u003e\n\u003cli\u003eDesigned for mounting solar panels directly onto suitable mesh fencing\u003c\/li\u003e\n\u003cli\u003eSupports \u003cstrong\u003eone framed solar panel per mounting set\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003evertical (portrait) installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003ehorizontal (landscape) installation\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eVertical mounting position of approximately \u003cstrong\u003e90°\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible with solar panel frame thicknesses of \u003cstrong\u003e30–35 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjustable upper clamps allow positioning according to fence mesh spacing\u003c\/li\u003e\n\u003cli\u003eUpper clamps attach to suitable mounting holes in the rear solar panel frame\u003c\/li\u003e\n\u003cli\u003eLower clamps secure the bottom of the solar panel against the fence\u003c\/li\u003e\n\u003cli\u003eSuitable for \u003cstrong\u003e656\/868 fence configurations\u003c\/strong\u003e as stated by the manufacturer\u003c\/li\u003e\n\u003cli\u003eNo separate ground-mounted solar frame required where a suitable mesh fence is available\u003c\/li\u003e\n\u003cli\u003eSpace-efficient mounting solution for suitable residential, commercial and off-grid solar projects\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px; table-layout:fixed;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003e\nGENERAL DATA\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"width:40%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eWorldwide Solar\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eModel 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMesh Fence Solar Panel Mounting System\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eMounting Component Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eSolar Panel Mesh Fence Clamp System\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eInstallation Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMesh Fence-Mounted Solar Installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePanel Orientation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eVertical (Portrait) or Horizontal (Landscape)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eTilt Angle\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eVertical (90°)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePanels Supported\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e1 framed solar panel per mounting set\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003e\nPANEL COMPATIBILITY\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eCompatible Panel Thickness\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e30–35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePanel Orientation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePortrait or Landscape\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003ePanel Attachment\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eUpper clamps attach through suitable mounting holes in the rear panel frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003e\nMESH FENCE COMPATIBILITY\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eCompatible Fence Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eSuitable mesh fencing\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eFence Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e656 \/ 868, as specified by the manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eUpper Clamp Adjustment\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eAdjustable according to fence mesh spacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eLower Clamp Arrangement\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eOne lower clamp positioned on each side of the panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"margin-top:25px;\"\u003eApplications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px; table-layout:fixed;\"\u003e\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"padding:10px; border:1px solid #ccc; background:#08B85A; color:#fff; font-weight:bold;\"\u003e\nSUITABLE INSTALLATIONS\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"width:70%; padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eMesh Fence Solar Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eVertical \/ Portrait Solar Panels\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eHorizontal \/ Landscape Solar Panels\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eResidential Solar Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eCommercial Solar Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eOff-Grid Solar Installations\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#08B85A;\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr style=\"background:#f7f7f7;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eGround Ballast Installation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#cc0000;\"\u003e✘\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; font-weight:500;\"\u003eFlat Roof Installation\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc; text-align:center; font-size:18px; color:#cc0000;\"\u003e✘\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:20px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#EAF8EF; border:1px solid #B8E8CA; border-left:5px solid #08B85A; padding:18px; vertical-align:top;\"\u003e\n\n\u003ch4 style=\"margin:0 0 12px 0; color:#008C45; font-size:18px;\"\u003e\nHow the Mesh Fence Mounting System Works\n\u003c\/h4\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThe upper clamps are first installed into suitable mounting holes on the rear of the solar panel frame. Their position can be adjusted according to the spacing of the fence mesh before the bolt assemblies are tightened.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThe solar panel is then positioned against the mesh fence. The wedge fittings are reinstalled and tightened to secure the upper section of the panel to the fence.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0;\"\u003e\nLower clamps are installed beneath the solar panel, with one clamp positioned on each side. The support piece, locking block and front pressure plate work together to hold the panel firmly against the fence.\n\u003c\/p\u003e\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ctable style=\"width:100%; border-collapse:collapse; margin:20px 0;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"background:#FFF8E5; border:1px solid #F2D98D; border-left:5px solid #E4A900; padding:18px; vertical-align:top;\"\u003e\n\n\u003ch4 style=\"margin:0 0 12px 0; color:#A87500; font-size:18px;\"\u003e\nImportant Installation Information\n\u003c\/h4\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nBefore installation, the purchaser or installer must confirm that installation of the system is permitted under applicable local laws, regulations and property requirements.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nInstallation should be carried out by a suitably qualified installer or professional where required by law. The mesh fence and supporting structure must be capable of safely supporting the solar panel and mounting system for the intended service life.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0 0 10px 0;\"\u003e\nThe product should not be installed in environments containing corrosive air or water, including areas exposed to acids or alkalis.\n\u003c\/p\u003e\n\n\u003cp style=\"margin:0;\"\u003e\nThe installed system should be inspected and maintained periodically. The manufacturer's instructions specify inspection intervals of no more than one year.\n\u003c\/p\u003e\n\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"font-size:13px; color:#666; margin-top:15px;\"\u003e\nProduct specifications and installation information are based on documentation supplied by the manufacturer. Suitability depends on the solar panel, mesh fence construction, installation location and applicable local requirements. The installer must confirm that the mesh fence and supporting structure are suitable for the intended photovoltaic installation before installation begins.\n\u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Worldwide Solar","offers":[{"title":"20 ft Container – 10080 Sets","offer_id":58470777487743,"sku":"WWS-BRK-KX1-M3-1P-C20-10080","price":9.0,"currency_code":"GBP","in_stock":true},{"title":"40 ft Container – 20160 Sets","offer_id":58470777520511,"sku":"WWS-BRK-KX1-M3-1P-C40-20160","price":9.0,"currency_code":"GBP","in_stock":true},{"title":"40 ft HC Container – 23040 Sets","offer_id":58470777553279,"sku":"WWS-BRK-KX1-M3-1P-C40HC-23040","price":9.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/6479\/0911\/files\/mesh-fence-solar-panel-mount-front.webp?v=1786466194"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0992\/6479\/0911\/collections\/Model-1-B-roof-top-commercial_7a928ed5-aef5-4aa2-bf44-2487d2a45a5a.webp?v=1789992160","url":"https:\/\/www.worldwide-solar.store\/collections\/wholesale-solar-mounting-systems-worldwide.oembed","provider":"Worldwide Solar Ltd","version":"1.0","type":"link"}